Skip navigation




Please use this identifier to cite or link to this item: http://aohindia.in/xmlui/handle/123456789/1725
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKar, Subrata-
dc.contributor.authorChakraborty, Monalisa-
dc.contributor.authorNandy, Papiya-
dc.contributor.authorBasu, Ruma-
dc.contributor.authorDasa, Sukhen-
dc.contributor.authorBhar, Durga Sankar-
dc.contributor.authorManchanda, Raj K.-
dc.contributor.authorKhurana, Anil-
dc.contributor.authorNayak, Debadatta-
dc.date.accessioned2019-04-05T10:57:07Z-
dc.date.available2019-04-05T10:57:07Z-
dc.date.issued2017-
dc.identifier.citationIndian Journal of Research In Homoeopathy Vol.11 (1)en_US
dc.identifier.urihttp://aohindia.in:8080/xmlui/handle/123456789/1725-
dc.description.abstractBackground: The objective of the study was to characterize homoeopathic nanomedicine Aurum metallicum and evaluate its biocompatibility, to explore its possible application as injectables. Metal‑based homoeopathic medicine, Aurum metallicum, was chosen as a model drug and the haemocompatibility of the drug at three different potencies 6C, 30C, and 200C were studied to find the justification of the drug as an injectable candidate for clinical application. Methods: The model drug Aurum metallicum at the three potencies was characterized by dynamic light scattering (DLS), zeta potential, field emission scanning electron microscopy (FESEM), and energy dispersive X‑ray analysis. Hemocompatibility of the homoeopathic medicine was performed by haemolysis assay. Red blood cell obtained from fresh human blood by centrifugation was incubated with Aurum metallicum. Haemoglobin release was measured using UV‑vis spectrophotometer at 540 nm. Results: The DLS and FESEM studies show a decrease of particle size with increasing potency. The zeta potential values show a fairly constant value measured at an interval of 10 days. The haemolysis percentage for 6C, 30C, and 200C was 9.73%, 8.16%, and 0.73%, respectively. Conclusion: The nanomedicine Aurum metallicum was nontoxic at all doses of 6C, 30C, and 200C. The haemolytic percentage also shows that 200C is nonhemolytic, showing haemolysis <2% as per the American Society for Testing and Materials guidelines. The undertaking of larger controlled and in‑depth qualitative studies is warranted.en_US
dc.description.sponsorshipCCRHen_US
dc.language.isoenen_US
dc.subjectHaemocompatibilityen_US
dc.subjectnanomedicineen_US
dc.titleCharacterization and haemocompatibility of Aurum metallicum for its potential therapeutic applicationen_US
dc.typeArticleen_US
Appears in Collections:Indian Journal of Research in Homoeopathy

Files in This Item:
File Description SizeFormat 
Original Article 5.pdf882.15 kBAdobe PDFView/Open
Show simple item record


Items in Archive are protected by copyright, with all rights reserved, unless otherwise indicated.